AVEC-CHEM OF-07 gas mask filter
NGOs and PUBLIC AGENCIES: PLEASE CONTACT US BEFORE PURCHASE
AVEC-CHEM OF-07 gas mask filter, NATO standardized, for use on gas mask or motorized respirator, ensures the filtration of toxic agents for the respiratory tract – in particular all CBRN toxic agents (vapours, gases, aerosols, contaminated dust) known.
69 in stock
Description
AVEC-CHEM OF-07 gas mask filter, NATO standardized, for use on gas mask or motorized respirator, ensures the filtration of toxic agents for the respiratory tract – in particular all CBRN toxic agents (vapours, gases, aerosols, contaminated dust) known.
Filter classified A2B2E1SXP3 D R & standardized CE EN 14387: 2004 – A1: 2008, manufactured in hardened polymer, excellent thermal and mechanical resistance. Thread (40×1/7 “ – 40mm NATO standard) compatible with all military and civilian NATO protection equipment or European & American manufacturing.
Provides filtering against solid and liquid particles, pepper spray (OC), radioactive particles, bacteria and rickettsia, fungi, toxins, viruses and riot control agents, vesicants, suffocants, blood, neurotoxic, incapacitating, herbicides, pesticides and ICT, nuclear & organic substances, organic arsenic compounds, toxic industrial chemicals (notably organic iodine compounds).
STORAGE LIFE: 20 YEARS – IN ITS HEAT-SEALED COVER
Product data & resistance to inspiration/exhalation (in pascal):
Technical Data | Breathing Resistance in Pa Breathing Resistance in Pa | ||
---|---|---|---|
Diameter | 110 mm | @ flow rate 30l/min. EN 1) AVEC-CHEM OF-07 260 <140 | @ flow rate 95l/min. EN 1) AVEC-CHEM OF-07 980 <600 |
Height | 85 mm | ||
Weight | 335 g ±5% | ||
Storage time | 20 years (factory sealed) |
- 40mm NATO thread – STANAG 4155 standardization (EN 148-1)
- NSN: 4240-16-007-1400
Operational life & filtration (in %) :
- Penetration resistance tested according to standard EN 14387 + A1 (70% humidity level – 30L/m flow rate)
- Resistance to penetration of radioactive iodines (and its organic components): according to standard DIN 58621
- Calculation of the effective lifespan in a contaminated zone: concentration/DAC (Dynamic Adsorption Capacity) – CONTACT US FOR THE MATHEMATICAL FORMULATION
Type and Class Particle filter efficiency @ flow rate 95l/m | Particle filter efficiency @ flow rate 95l/m | |||
---|---|---|---|---|
A2 – organic gases and vapors | SX – CG, CK, PS | Sodium Chloride NaCl (S) Paraffin oil (L) | EN 99,95 99,95 | NBC-77 SOF >99,999 >99,999 |
B2 – inorganic gases and vapors | P3 – particles | |||
E1 – acid gases and vapors | D- dust | |||
R- reusable | ||||
Effective filtration :
Solid and liquid particles, pepper spray (OC), smoke-emitting substances, radioactive particles, bacteria and rickettsiae, fungi, toxins, viruses and riot control agents (regulators, sternutators). , blister agents), blister agents, choking agents, blood agents, nerve agents, incapacitating agents, herbicides, pesticides and TICs, such as bromoacetone, CS, CR, CN, nuclear substances, organic substances, organic arsenic compounds – diphenyldichlorarsine – CLARK I (DA), diphenylcyanoarsine – CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulfur mustard gas (H), sulfuric gas (HD), T mustard gas, Q mustard gas, nitrogen mustard gas (HN1, HN2, HN3), lewisite (L), mixed mustard gas (HL), phosgene oxime (CX), phosgene (CG), diphosgene (DP), chloropicrin (PS), hydrocyanic acid (AC), cyanogen chloride (CK), arsine (SA), G agents: sarin (GB), cyclo sarin (GF), soman (GD), tabun (GA) , IVA (GV), V agents: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: organic or inorganic acid vapors, hydroxides, organic solvents with a boiling point higher than 65°C, ammonia, amines, inorganic gases and acids, flue gases of agricultural chemicals, other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulfur oxides, chloroacetic acid, aldehydes , mixtures of inorganic acids and organic substances, mercury vapors, radioactive iodine, organic iodine compounds (Iodomethane, 129, 131), radioactive particles.
Testing Gas | Concentration of Testing Gas | Breakthrough Time in Minutes EN | OF-07 | DAC in Grams AVEC-CHEM OF-07 | |||
---|---|---|---|---|---|---|---|
ppm | mg/I | ||||||
A2 | Cyclohexane | C₆H₁₂ | 5000 | 17.5 | 35 | 38 | 19.550 |
B2 | Chlorine | Cl₂ | 5000 | 15 | 25 | >28 | 12.600 |
Hydrogen Sulphide | H₂S | 5000 | 7.1 | 40 | >60 | >12.500 | |
Hydrogen Cyanide | HCN | 5000 | 5.6 | 25 | >30 | >5.040 | |
E1 | Sulphur Dioxide | SO₂ | 1000 | 13.3 | 20 | >60 | >4.860 |
SX | Cyanogen chloride | CICN | 2500 | 6.28 | 20 | >30 | >5.652 |
Chloropicrin | CCI₃NO₃ | 5000 | 33.55 | 20 | >30 | >30.195 | |
Phosgene | COCl₃ | 5000 | 20.24 | 20 | >25 | >15.180 | |
THE CARTRIDGE MUST BE CHANGED IMMEDIATELY UPON THE SATURATION POINT REACHED
Storage :
- In a cool room, without light, regularly ventilated, without any electrical or chemical equipment
- Maximum relative humidity of 95%
- Temperatures in a range between -30° and +50°C (SEALED CARTRIDGE)
After use :
- Once the cartridge is saturated :
- Comply with orders from civil or military authorities
- IF YOU ARE IN SURVIVAL MODE :
- Store the filters in an airtight bag & bury them in an identified area (to be considered polluted and unusable)
- If you can, seal the cartridges in concrete, lead…
Additional information
Brand | Avec Chem |
---|---|
Shipped from | Czech Republic |
FREE SHIPPING
On orders over $500.
CONSULTATION FOR SHELTER
we answer your questions within 48 hours
SUPPORT 24/7
Online support services