AVEC-CHEM NBC-SCF gas mask filter

69,90 

NGOs and PUBLIC AGENCIES: PLEASE CONTACT US BEFORE PURCHASE

AAVEC-CHEM NBC-SCF gas mask filter for use on gas mask or motorized respirator, ensures the filtration of toxic agents for the respiratory tract – in particular all known CBRN toxic agents (vapours, gases, aerosols, contaminated dusts). Cartridge classified A2B2E2K2HgNOCOSXP3 D R & standardized CE EN 14387: 2004 – A1: 2008, manufactured in hardened polymer, excellent thermal and mechanical resistance. Thread (40×1/7 “ – 40mm NATO standard) compatible with all NATO military and civilian protection equipment or European or American manufacturing.

11 in stock

AVEC_NBC_FIL_NBC-SCF

Description

AVEC-CHEM NBC-SCF gas mask filter for use on gas mask or motorized respirator, ensures the filtration of toxic agents for the respiratory tract – in particular all known CBRN toxic agents (vapours, gases, aerosols, contaminated dusts).

 

Cartridge classified A2B2E2K2HgNOCOSXP3 D R & standardized CE EN 14387: 2004 – A1: 2008, manufactured in hardened polymer, excellent thermal and mechanical resistance. Thread (40×1/7 “ – 40mm NATO standard) compatible with all NATO military and civilian protection equipment or European or American manufacturing.

 

The filter provides protection against solid and liquid aerosols, smoke-producing agents, radioactive particles, microorganisms, fibres (e.g. asbestos), fumes of organic or inorganic acids, hydroxides, organic solvents with the boiling point above 65°C, ammonia, amines, inorganic and acid gases, agricultural chemical combustion gases, tear, irritant and other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, bromoacetone, nitogen oxide, nitrogen dioxide, carbon monoxide, phosgene, cyanogen chloride, phosphoric acid and its organic derivatives, chloracetic acid, aldehydes, mixtures of inorganic acids, and organic substances, mercury vapours, etc.

STORAGE LIFE: 07 YEARS – IN ITS HEAT-SEALED COVER

Product data & resistance to inspiration/exhalation (in pascal) :

Technical DataBreathing Resistance in Pa Breathing Resistance in Pa
Diameter110 mm@ flow rate 30l/min. EN 1) <190@ flow rate 95l/min. EN 1) <870
Height95 mm
Weight450 g ±1,5%
Storage time07 years (factory sealed)

 

  • 40mm NATO thread – STANAG 4155 standardization (EN 148-1) / GOST 876275

Lifespan & filtration (in %) :

  • Penetration resistance tested according to standard EN 14387 + A1 (70% humidity level – 30L/m flow rate)
  • Resistance to penetration of radioactive iodines (and its organic components): according to standard DIN 58621
  • Calculation of the effective lifespan in a contaminated zone: concentration/DAC (Dynamic Adsorption Capacity) – CONTACT US FOR MATHEMATICAL FORMULATION
Type and Class Particle filter efficiency @ flow rate 95l/mParticle filter efficiency @ flow rate 95l/m
A2 – organic gases and vaporsSX – CG, CK, PSSodium Chloride NaCl (S) Paraffin oil (L)EN 99,95 99,95>99,999 >99,999
B2 – inorganic gases and vaporsP3 – particles
E2 – acid gases and vaporsD- dust
K2 – ammonia and aminesR- reusable
Hg – mercury vaporsREACTOR

Effective filtration :

Solid and liquid particles, pepper spray (OC), smoke-emitting substances, radioactive particles, bacteria and rickettsiae, fungi, toxins, viruses and riot control agents (regulators, sternutators). , blister agents), blister agents, choking agents, blood agents, nerve agents, incapacitating agents, herbicides, pesticides and TICs, such as bromoacetone, CS, CR, CN, nuclear substances, organic substances, organic arsenic compounds – diphenyldichlorarsine – CLARK I (DA), diphenylcyanoarsine – CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulfur mustard gas (H), sulfuric gas (HD), T mustard gas, Q mustard gas, nitrogen mustard gas (HN1, HN2, HN3), lewisite (L), mixed mustard gas (HL), phosgene oxime (CX), phosgene (CG), diphosgene (DP), chloropicrin (PS), hydrocyanic acid (AC), cyanogen chloride (CK), arsine (SA), G agents: sarin (GB), cyclo sarin (GF), soman (GD), tabun (GA) , IVA (GV), V agents: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: organic or inorganic acid vapors, hydroxides, organic solvents with a boiling point higher than 65°C, ammonia, amines, inorganic gases and acids, flue gases of agricultural chemicals, other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulfur oxides, chloroacetic acid, aldehydes , mixtures of inorganic acids and organic substances, mercury vapors, radioactive iodine, organic iodine compounds (Iodomethane, 129, 131), radioactive particles.

 

Type

Test gas

Breakthroug time in minutes

Concentration of testing gas at flow rate 30 l/min

Breakthrough concentration

DAC (Dynamic Adsorbtion Capacity) in grams

EN 1)

Filter AVEC2)

% vol

mg/l

ppm

EN 1)

Filter AVEC2)

A2

Cyclohexane (C6H12)

35

>40

0,5

17,5

10

18,375

>21,000

Chlorine (Cl2)

20

>25

0,5

15

0,5

9,000

>11,250

B2

Hydrogen Sulphide (H2S)

40

>60

0,5

7,1

10

8,520

>12,780

Hydrogen cyanide (HCN)

25

>30

0,5

5,6

10

4,200

>5,040

E2

Sulphur dioxide (SO2)

20

>25

0,5

13,3

5

7,980

>9,975

K2

Ammonia (NH3)

40

>40

0,5

3,5

25

4,200

>4,200

Hg

Mercury (Hg)

100 hours

>170 hours

13 mg/m3

0,1 mg/m3

2,340

>3,900

NO

Nitrogen oxide (NO)

20

>20

0,25

3,1

5

1,860

>1,860

Nitrogen dioxide (NO2)

20

>25

0,25

4,8

5

2,880

>3,600

CO

Carbon monoxide

(CO)

20

>20

0,5

3,5

25

2,100

>2,100

SX

Phosgene (COCl3)

20

>30

0,5

20,24

0,5

12,144

>18,216

 

THE CARTRIDGE MUST BE CHANGED IMMEDIATELY UPON THE SATURATION POINT REACHED

Storage :

  • In a cool room, without light, regularly ventilated, without any electrical or chemical equipment
  • Maximum relative humidity of 95%
  • Temperatures in a range between -30° and +50°C (SEALED CARTRIDGE)

After use :

  • Once the cartridge is saturated:
    • Comply with recovery orders from civil or military authorities
  • IF YOU ARE IN SURVIVAL MODE :
    • Store the filters in an airtight bag & bury them in an identified area (to be considered polluted and unusable)
    • If you can, seal the cartridges in concrete, lead…

Additional information

Brand

Avec Chem

Shipped From

Czech Republic

FREE SHIPPING

On orders over $500.

CONSULTATION FOR SHELTER

we answer your questions within 48 hours

SUPPORT 24/7

Online support services